Home › Blog › Testing Air Purifiers Against Formaldehyde: CADR Measurement at IUTA Duisburg

Testing Air Purifiers Against Formaldehyde: CADR Measurement at IUTA Duisburg

The IUTA institute in Duisburg tests air purifiers in a 30 m³ chamber to the Chinese standard GB/T 18801 — with the AL4021 recording formaldehyde decay curves at high time resolution, accredited to ISO/IEC 17025.

AT
Aero-Laser Team
Aero-Laser GmbH
January 2026 · 1 min read

Formaldehyde is one of the most common gaseous pollutants in indoor spaces — and a growing market of air purifiers claims to remove it. Whether a device actually does is a measurement question, and answering it reproducibly is the business of the Institut für Energie- und Umwelttechnik (IUTA) in Duisburg, which has been testing air purifiers for many years.

The task

Purification performance is quantified as the Clean Air Delivery Rate (CADR), following the Chinese standard GB/T 18801:2015 — the internationally dominant test protocol for this device class. A defined initial concentration of formaldehyde is introduced into a 30 m³ test chamber, and the exponential decay over time is measured twice: once without and once with the air cleaner operating. The difference between the two decay constants yields the CADR.

The setup

The decisive requirement is time resolution. A decay curve is only as good as the number of points on it, which rules out discontinuous sampling methods with lab turnaround. IUTA records the curves with an Aero-Laser AL4021 continuous formaldehyde analyzer, which covers the entire relevant concentration range — from the spiked starting level down to indoor background. The measurements are accredited to DIN EN ISO/IEC 17025:2018.

Why it matters

CADR figures end up on product packaging and in purchase decisions; the chain of trust behind them runs through an accredited lab and, ultimately, through the analyzer recording the decay. If your lab runs chamber-based device or material testing, the AL4021’s combination of range, response time and accreditation track record is worth a close look — our engineers will gladly discuss your chamber setup.

Talk to an Application Engineer

Got a measurement challenge this article doesn't cover? Our team responds within one business day — no sales funnel, direct expert contact.